Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

GW Instek GDM-8261A - 6 1/2 (1,200,000 Counts) Digit Dual Measurement Multimeter

6 1/2 (1,200,000 Counts) Digit Dual Measurement Multimeter

GW Instek

Rated 0 / 5 (0 reviews)

Category : Multimeters

by quote only add to cart

Documents:
Brochure

Overview
Features
Specifications
Calibration

Boost Your Measurement Speed & Efficiency

The GDM-8261 is a high precision 6 ½ digit Digital Multimeter with dual measurement displays, 11 measurement functions and 10 math functions at high accuracy (35ppm DC voltage accuracy) to accommodate the most frequently performed parameter measurements in various application fields today.

The GDM-8261A adopts a scanner card, which carries 16 V-Channels and 2 I-Channels, to facilitate the measurements of multiple-test points on either a device or multiple devices all at a press of a button. With this multi-point measurement capability, the GDM-8261A can be used as a semi-auto ATE System to increase the throughput of manufacturing test or as a data logger to perform long term monitoring or characterization of a DUT. A PC Software, DMM-Viewer, is available with GDM-8261A to support multi-channel panel setting and data logging of the scanner card. Besides, a LabVIEW driver is also supported to help user create his/her own virtual instrument on the PC screen for easy programming. For ATE system measurements or remote control applications, both USB and RS-232 Interfaces are provided as standard, and either GPIB or LAN can be selected as optional interface for the GDM-8261A.

 

This product has been discontinued. Our replacement recommendation is the GDM-9061 - GW Instek High Precision Bench DMM

Quality Discontinued Clearance Product
  • 6 1/2 Digit Display:1,200,000 counts
  • DCV Basic Accuracy:0.0035%
  • Dual Measurements to perform two selected measurements simultaneously
  • Bright Vacuum Fluorescent Display (VFD)
  • Provide AC+DC Voltage or Current Measurement Functions
  • 11 Measurement Functions & 10 Math Functions
  • High Resolution: Up to 100pA with DCI and 1nA with ACI Measurements
  • Temperature Measurement (RTD & Thermocouple) from -200°C ~ +1820°C
  • High Transmission Speed: Up to 2,400 readings/sec through the USB
  • Standard Interfaces:USB, RS232C, Digital I/O
  • Optional Interfaces:GPIB or LAN
  • Optional Scanner Card:GDM-SC1 (V ch x16, I ch x2)
  • Free PC software:DMM Viewer , LabVIEW Driver

 

 

Function Range(3) Resolution Input Resistance
etc.
24 Hour 23°C± 1°C 90 Day 23°C± 5°C 1 Year 23°C± 5°C Temperature Coefficient 0°~ 18°C /28°~ 55°C
DC Voltage 100.0000 mV 0.1μV 10MΩ or >10GΩ 0.0030 + 0.0030 0.0040 + 0.0035 0.0050 + 0.0035 0.0005 + 0.0005
1.000000 V 1μV 10MΩ or >10GΩ 0.0015 + 0.0004 0.0020 + 0.0005 0.0035 + 0.0005 0.0005 + 0.0001
10.00000 V 10μV 11.11MΩ±1% 0.0020 + 0.0006 0.0030 + 0.0007 0.0048 + 0.0007 0.0005 + 0.0001
100.0000 V 0.1mV 10.1MΩ±1% 0.0020 + 0.0006 0.0035 + 0.0006 0.0081 + 0.0006 0.0005 + 0.0001
1000.000 V 1mV 10.1MΩ±1% 0.0025 + 0.0006 0.0044 + 0.0010 0.0090 + 0.0010 0.0005 + 0.0001
Resistance(4) 100.0000 Ω 100μΩ 1 mA 0.0030 + 0.0030 0.008 + 0.004 0.010 + 0.004 0.0008 + 0.0005
1.000000 kΩ 1mΩ 1 mA 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 0.0008 + 0.0001
10.00000 kΩ 10mΩ 100μA 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 0.0008 + 0.0001
100.0000 kΩ 100mΩ 10μA 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 0.0008 + 0.0001
1.000000 MΩ 1μΩ 3.5μA 0.0020 + 0.0010 0.008 + 0.001 0.010 + 0.001 0.0010 + 0.0002
10.00000 MΩ 10Ω 350nA 0.0150 + 0.0010 0.020 + 0.001 0.040 + 0.001 0.0030 + 0.0004
100.0000 MΩ 100Ω 350 nA//10 MΩ 0.3000 + 0.0100 0.800 + 0.010 0.800 + 0.010 0.1500 + 0.0002
DC Current 100.0000 μA 100pA < 0.015 V 0.010 + 0.020 0.04 + 0.025 0.05 + 0.025 0.002 + 0.0030
1.000000 mA 1nA < 0.15 V 0.007 + 0.005 0.03 + 0.005 0.05 + 0.005 0.002 + 0.0005
10.00000 mA 10nA < 0.07 V 0.005 + 0.010 0.03 + 0.020 0.05 + 0.020 0.002 + 0.0020
100.0000 m A 0.1μA < 0.7 V 0.010 + 0.004 0.03 + 0.005 0.05 + 0.005 0.002 + 0.0005
1.000000 A 1μA < 0.8 V 0.050 + 0.006 0.08 + 0.010 0.10 + 0.010 0.005 + 0.0010
10.00000 A 10μA < 0.5 V 0.100 + 0.008 0.12 + 0.008 0.15 + 0.008 0.005 + 0.0008
Continuity 1000.000 Ω 0.001Ω 1 mA 0.002 + 0.030 0.008 + 0.030 0.010 + 0.030 0.001 + 0.002
Diode Test 1.000000 V 1μV 1 mA 0.002 + 0.010 0.008 + 0.020 0.010 + 0.020 0.001 + 0.002
True RMS 
AC Voltage(6)
100.0000 mV 0.1μV 3Hz - 5Hz 1.00 + 0.03 1.00 + 0.04 1.00 + 0.04 0.100 + 0.004
5Hz - 10Hz 0.35 + 0.03 0.35 + 0.04 0.35 + 0.04 0.035 + 0.004
10Hz - 20kHz 0.04 + 0.03 0.05 + 0.04 0.06 + 0.04 0.005 + 0.004
20kHz - 50kHz 0.10 + 0.05 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
50kHz - 100kHz 0.55 + 0.08 0.60 + 0.08 0.60 + 0.08 0.060 + 0.008
100kHz -300kHz 4.00 + 0.50 4.00 + 0.50 4.00 + 0.50 0.200 + 0.020
1.000000 V to 750.000 V(5) 1μV ~ 1mV 3Hz - 5Hz 1.00 + 0.02 1.00 + 0.03 1.00 + 0.03 0.100 + 0.003
5Hz - 10Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003
10Hz - 20kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003
20kHz - 50kHz 0.10 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
50kHz - 100kHz 0.55 + 0.08 0.60 + 0.08 0.60 + 0.08 0.060 + 0.008
100kHz -300kHz 4.00 + 0.50 4.00 + 0.50 4.00 + 0.50 0.200 + 0.020
True RMS 
AC Current(6)
1.000000 mA 1nA 3Hz – 5Hz 1.00 + 0.04 1.00 + 0.04 1.00 + 0.04 0.100 + 0.006
5Hz – 10Hz 0.30 + 0.04 0.30 + 0.04 0.30 + 0.04 0.035 + 0.006
10Hz – 5kHz 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.015 + 0.006
5kHz – 10kHz 0.20 + 0.25 0.20 + 0.25 0.20 + 0.25 0.030 + 0.006
10.00000 mA 10nA 3Hz – 5Hz 1.10 + 0.06 1.10 + 0.06 1.10 + 0.06 0.200 + 0.006
5Hz – 10Hz 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 0.100 + 0.006
10Hz – 5kHz 0.15 + 0.06 0.15 + 0.06 0.15 + 0.06 0.015 + 0.006
5kHz – 10kHz 0.35 + 0.70 0.35 + 0.70 0.35 + 0.70 0.030 + 0.006
100.0000 mA 100nA 3Hz – 5Hz 1.00 + 0.04 1.00 + 0.04 1.00 + 0.04 0.100 + 0.006
5Hz – 10Hz 0.30 + 0.04 0.30 + 0.04 0.30 + 0.04 0.035 + 0.006
10Hz – 5kHz 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.015 + 0.006
5kHz – 10kHz 0.20 + 0.25 0.20 + 0.25 0.20 + 0.25 0.030 + 0.006
1.000000 A 1μA 3Hz – 5Hz 1.00 + 0.04 1.00 + 0.04 1.00 + 0.04 0.100 + 0.006
5Hz – 10Hz 0.30 + 0.04 0.30 + 0.04 0.30 + 0.04 0.035 + 0.006
10Hz – 5kHz 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.015 + 0.006
5kHz – 10kHz 0.35 + 0.70 0.35 + 0.70 0.35 + 0.70 0.030 + 0.006
10.00000 A 10μA 3Hz – 5Hz 1.10 + 0.06 1.10 + 0.06 1.10 + 0.06 0.100 + 0.006
5Hz – 10Hz 0.35 + 0.06 0.35 + 0.06 0.35 + 0.06 0.035 + 0.006
10Hz – 5kHz 0.15 + 0.06 0.15 + 0.06 0.15 + 0.06 0.015 + 0.006
5kHz – 10kHz 0.35 + 0.70 0.35 + 0.70 0.35 + 0.70 0.030 + 0.006
Frequency / Period 100.0000mV to 750.000V(5) 3Hz - 5Hz 0.1 0.1 0.1 0.005
5Hz - 10Hz 0.05 0.05 0.05 0.005
10Hz - 40Hz 0.03 0.03 0.03 0.001
40Hz -300kHz 0.006 0.01 0.01 0.001
Temperature (RTD) -200 °C ~ 600 °C 0.001 °C 0.06 °C (typical) 0.005 °C / °C (typical)
Temperature (Thermocouple) -200 °C ~ + 1300 °C 0.002 °C E / J / T / K / N 0.3 °C (typical) 0.004 °C / °C (typical)
-50 °C ~ + 1820 °C 0.01 °C R / S / B 1 °C 0.14 °C / °C
Display VFD, Tow Colors Display Note :
Interface RS -232C, USB, Digital I/O 1. All specifications are ensured only under a single display.
Power Source AC 100 V / 120 V / 220 V / 240 V ±10% 2. Accuracy : ± (% of reading + % of range)
Power Line Frequency 45 Hz to 66 Hz and 360 Hz to 440 Hz 3. 20% overrange on all ranges, except 1000Vdc, 750Vac and 10A.
Power Consumption Max. 25VA 4. Resistance is for 4-wire ohms function, or 2-wire ohms with REL on.
Dimensions 265(W) x 107(H) x 350(D) mm 5. 750Vac range limited to 100kHz
Weight Approx. 3.1kg without option 6. AC Characteristics are for sinewave input > 5% of range.

Do you have a 6 1/2 (1,200,000 Counts) Digit Dual Measurement Multimeter that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your 6 1/2 (1,200,000 Counts) Digit Dual Measurement Multimeter calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the GW Instek GDM-8261A - 6 1/2 (1,200,000 Counts) Digit Dual Measurement Multimeter

6 1/2 (1,200,000 Counts) Digit Dual Measurement Multimeter

Name :

Email :

Title :

Review: