GW Instek GSP-930 - GSP-9 - 3GHz Spectrum Analyzer
GSP-930 provides a high frequency-stability of 25ppb (0.025ppm) and a very low noise floor of -142dBm (Pre-amplifier on) as the high sensibility measurement base. The flexible selection among 58 RBW ranges along with Spectrogram and Topographic features enable GSP-930 to capture and display transient, drifting and hopping signals in detail. The mixture of frequency domain information and time domain information facilitates the tracing of RF signal variations over time. Other remarkable features like Spectrum Emission Mask (SEM), Power Measurements, AM/FM Analysis and TOI/CNR/CSO/CTB measurements, make GSP-930 a useful instrument right fit into a broad range of applications.
The user friendly design of GSP-930 helps reduce user’s stress and anxiety in using a high-tech instrument. To help user easily get access to the regulations and definitions of the measurement terms under current operation, the built-in On-Screen-Help provides definition descriptionon the screen to guide user through measurement processes without checking into documents. The widely used Icons on the display clearly indicate the current setting and operation status of the product, allowing user to handle the measurement scenario all at a glance. The wake-up clock automatically turns on the power of GSP-930 at user’s pre-set time, which can be used to warm up the instrument in advance before the measurements are made to ensure the accuracy of measurement results. The Pass/Fail Limit function allows user to perform repetitive go/no-go measurements by template inspection instead of time-consuming value reading. The Sequence function provides an easy programming feature for user to edit and run measurement routines on GSP-930 screen without the need of a PC.
GSP-930 is equipped with various interfaces, including LXI, USB, RS-232 and GPIB (optional). The IVI driver is available for the remote control software development by means of LabVIEW or LabWindows/CVI. A Micro SD slot and a USB Host interface enable the memory size expansion for mass data storage. An IF output (886MHz) is provided as the intermediate frequency signal of RF inputfor users to develop their own applications. Carrying abundant communication interfaces, user-friendly operation, large screen display, light weight, compact size, and battery power operation(1), GSP-930 is developed upon a high-tech platform to provide ultimate customer benefits.
- Frequency Range: 9kHz ~ 3GHz
- High Frequency Stability: 25ppb (0.025ppm)
- RBW: 10Hz ~ 10kHz in 1-3 steps, 10kHz ~ 1MHz in 10% adjustable steps
- Phase Noise: -88dBc/Hz @1GHz, 10kHz Offset
- Built-in Measurement Functions: Channel Power, N-dB bandwidth, OCBW, ACPR, SEM, TOI, CNR, CTB, CSO
- Built-in Spectrogram and Topographic Display Modes
- Gate Sweep Function
- 1Hz Resolution Marker Counter
- AM/FM Demodulation Analysis
- 886MHz IF Output for User’s Extended Applications
- Various Interface: USB Host/Device, RS-232, LXI, Micro SD, GPIB (Optional)
- 8.4 large TFT LCD display with SVGA resolution of 800 *600
- DVI-I Output for External Digital Display
- Built-in Preamplifier, 50dB Attenuator, and Sequence Function
- Optional 6GHz Power Sensor, Tracking Generator, Battery Back
Frequency | |||
Frequency | |||
Range | 9 kHz to 3.0 GHz | ||
Resolution | 1 Hz | ||
Frequency Reference | |||
Accuracy | ±[(period since last adjustment X aging rate) + stability over temperature + supply voltage stability | ||
Aging Rage | ±2 ppm max. | 1 year after last adjustment | |
Frequency Stability over Temperature | ±0.025 ppm | 0 to 50 °C | |
Supply Voltage Stability | ±0.02 ppm | ||
Frequency Readout Accuracy | |||
Start, Stop, Center, Marker | ±(marker frequency indication X frequency reference accuracy + 10% x RBW + frequency resolution1) | ||
Sweep points | 601 | Span > 0 | |
6 to 601 | Span = 0 | ||
Marker Frequency Counter | |||
Resolution | 1 Hz, 10 Hz, 100 Hz, 1 kHz | ||
Accuracy | ±(marker frequency indication X frequency reference accuracy + counter resolution) |
RBW/Span >=0.02 ;
Mkr level to DNL>30 dB
|
|
Frequency Span | |||
Range | 0 Hz (zero span), 100 Hz to 3 GHz | ||
Resolution | 1 Hz | ||
Accuracy |
|
||
Phase Noise
|
|||
|
Offset from Carrier
|
|
Fc =1 GHz; RBW = 1 kHz, VBW = 10 Hz;Average ≥ 40
|
10 kHz
|
<-88 dBc/Hz
|
Typical2
|
|
100 kHz
|
<-95 dBc/Hz
|
Typical
|
|
1 MHz
|
<-113 dBc/Hz
|
Typical
|
|
Resolution Bandwidth (RBW) Filter | |||
Filter Bandwidth | 10 Hz to 3 kHz in 1-3-10 sequence |
-3dB bandwidth
subtotal: 6 filters
|
|
10 kHz to 1 MHz, increment in 10% step |
-3dB bandwidth;
min. RBW = 10 kHz @ zero span
Subtotal: 49 filters
|
||
200 Hz, 9 kHz, 120 kHz | -6dB bandwidth | ||
Accuracy | ± 8%, RBW ≥ 750 kHz |
|
|
± 5%, RBW < 750 kHz | Nominal | ||
Shape Factor | < 4.5:1 | Normal Bandwidth ratio: -60dB:-3dB | |
Video Bandwidth (VBW) Filter | |||
Filter Bandwidth | 1 Hz to 1 MHz in 1-3-10 sequence | -3dB bandwidth | |
|
Amplitude | |||
Amplitude Range | |||
Measurement Range | 100 kHz to 1 MHz | Displayed Average Noise Level (DANL) to 18 dBm | |
1 MHz to 10 MHz | DANL to 21 dBm | ||
10 MHz to 3 GHz | DANL to 30 dBm | ||
Attenuator | |||
Input Attenuator Range | 0 to 50 dB, in 1 dB step | Auto or manual setup | |
Maximum Safe Input Level | |||
Average Total Power | £ +33 dBm | Input attenuator ≥10 dB |
|
DC Voltage | ± 50 V | ||
1 dB Gain Compression
|
|||
|
Total Power at 1st Mixer
|
> 0 dBm
|
Typical;Fc ≥50 MHz; preamp. off
|
|
Total Power at the Preamp
|
> -22 dBm
|
Typical;Fc ≥50 MHz; preamp. on
|
|
|
|
mixer power level (dBm)= input power (dBm)-attenuation (dB)
|
Displayed Average Noise Level (DANL) | |||
Preamp off | 0 dB attenuation; RBW 10 Hz; VBW 10 Hz; span 500 Hz; reference level = -60dBm; trace average ≥ 40 | ||
9 kHz to 100 kHz | < -93 dBm, |
|
|
100 kHz to 1 MHz | < -90 dBm - 3 x (f/100 kHz) dB | ||
1 MHz to 10 MHz | < -122 dBm | ||
10 MHz to 3 GHz | < -122 dBm | ||
Preamp on | 0 dB attenuation; RBW 10 Hz; VBW 10Hz; span 500 Hz; reference level = -60dBm; trace average ≥ 40 | ||
100 kHz to 1 MHz | < -108 dBm - 3 x (f/100 kHz) dB |
|
|
1 MHz to 10 MHz | < -142 dBm | ||
10 MHz to 3 GHz | < -145 dBm + 3 x (f/1 GHz) dB | ||
Level Display Range | |||
Scales | Log, Linear | ||
Units | dBm, dBmV, dBuV, V, W | ||
Marker Level Readout | 0.01 dB | Log scale | |
0.01 % of reference level | Linear scale | ||
Level Display Modes | Trace, Topographic, Spectrogram | Single / split Windows | |
Number of Traces | 4 | ||
Detector | Positive-peak, negative-peak, sample, normal, RMS(not Video) | Can be setup for each trace separately | |
Trace Functions | Clear & Write, Max/Min Hold, View, Blank, Average | ||
Absolute Amplitude Accuracy
|
|||
|
Absolute Point
|
Center=160 MHz ; RBW 10 kHz; VBW 1 kHz; span 100 kHz; log scale; 1 dB/div; peak detector; 20 to 30°C; signal 0 dBm
|
|
|
Preamp off
|
± 0.3 dB
|
Ref level 0 dBm; 10 dB RF attenuation
|
|
Preamp on
|
± 0.4 dB
|
Ref level -30 dBm; 0 dB RF attenuation
|
Frequency Response | |||
Preamp off | Attenuation: 10 dB; Reference: 160 MHz; 20 to 30°C | ||
100 kHz to 2.0 GHz | ± 0.5 dB | ||
2.0GHz to 3.0 GHz | ± 0.7 dB | ||
Preamp on | Attenuation: 0 dB; Reference: 160 MHz; 20 to 30°C |
Do you have a GSP-9 - 3GHz Spectrum Analyzer that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your GSP-9 - 3GHz Spectrum Analyzer calibrated today! Click Here!
There are currently no reviews for this product.
Recommended Accessories for the GSP-9 - 3GHz Spectrum Analyzer
Tracking Generator
DC Battery Pack
Soft Carrying Case for GSP-930