Fluke I6000S-FLEX-24 - i6000s Flex AC Current Probe (24 inch)

i6000s Flex AC Current Probe (24 inch)

Fluke

Rated 0 / 5 (0 reviews)

Category : Accessories

by quote only add to cart

Documents:

Overview
Features
Specifications
Calibration

The i6000sflex is an AC current probe utilising the Rogowski principle. It can be used to measure currents up to 6000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Electrical Characteristics
Current ranges 60 A / 600 A / 6000 A AC rms
Output sensitivity (AC coupled) 50 mV /5 mV / 0.5 mV per A
Load impedance 100 kOhm minimum
Accuracy (at +25°C) ±1% of range (45 – 65 Hz)
Linearity (10% to 100% of range) ±0.2% of reading
Noise 8 mV AC rms (60 A)
2 mV AC rms (600/6000 A)
Frequency range 10 Hz to 50 kHz (-3 dB)
Phase error < ±1° (45 – 65 Hz)
±10° (at 20 kHz)
Position sensitivity (with cable > 25 mm from the coupling) ±2% of range
External field (with cable > 200 mm from the head) ±1% of range
Power supply 2 x AA MN 1500 LR6 alkaline
400 Hours, low battery indicator or dedicated ext power supply
Temperature coefficient ±0.08% of reading per ° C
Working voltage (see Safety Standards section) 600 V AC rms or DC
General Characteristics
Head cable length (double insulated) 610 mm (24 in) I6000s Flex-24
915 mm (36 in) I6000s Flex-36
Head cable diameter 14.3 mm
Head bend radius 38.1 mm
Cable length (head to electronics) 2 m
Output connection 0.5 m cable terminated with safety BNC connector
Supplied with 4 mm safety plug adaptor
Operating temperature range -20 to +90°C (head)
-20 to +85°C (electronics)
Storage temperature range -40 to +105°C (head)
-20 to +85°C (electronics)
Operating humidity 15% to 85% (non condensing)
Weight 180 g (head), 190 g (electronics)
Safety Standards
BS EN 61010 1: 2001
BS EN 61010 2-032: 2002
BS EN 61010 031: 2002
600 V rms, Category III, Pollution degree 2  
EMC standards BS EN 61326: 1998 +A1, A2, and A3
Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz

Do you have a i6000s Flex AC Current Probe (24 inch) that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your i6000s Flex AC Current Probe (24 inch) calibrated today! Click Here!

 

There are currently no reviews for this product.

 