Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

GW Instek GPT-12002 - AC 200VA AC/DC Withstanding Voltage Electrical Safety Analyzer

AC 200VA AC/DC Withstanding Voltage Electrical Safety Analyzer

GW Instek

Category : Safety / Testing / Compliance Instr.

by quote only Add to Cart

Documents:
Brochure Datasheet User's Manual

Overview
Features
Information
Calibration

GW Instek introduces the flagship model (200VA output capacity) safety analyzer-the GPT-12000 series, which is the first safety analyzer in the world to comply with IEC 61010-2-034 (Safety requirement for electrical requirement for measurement, control and laboratory use – particular requirements for measurement equipment for insulation resistance and test equipment for electric strength), which stipulates that the requirements of the software and hardware interfaces must be followed while designing high voltage and insulation resistance test and measurement instruments so as to ensure that users are provided with necessary protection and warning while using the instruments.

 

Analyze Your Safety Tests

  • Meets IEC 61010-2-034 design requirements
  • High Accuracy and High Resolution Testing Performance
  • Flexible supplementary testing mechanism
  • Statistic and analysis
  • Sweep and tabular automatic test
  • Complete test data retrieval interface
  • 200VA AC Test Capacity
  • Comply with IEC 61010-2-034
  • 7”TFT LCD
  • Manual / Auto Mode
  • True RMS Current Measurement
  • Zero Crossing Turn-on Operation
  • Controllable Ramp-up & Ramp-down Time
  • Capacitive Load Testing Capability up to 47μF
  • Statistics Function
  • Sweep Function for DUT Characteristic Analysis
  • USB Storage available
  • Rear panel output available
  • Interface : RS-232C, USB host/device, Signal I/O and GPIB (optional)
  • Universal power input

General

Functions
AC WithstandingYes
DC WithstandingYes
Insulation ResistanceNo
Ground BondNo
Ground ContinuityYes
Display7" Color LCD
Power SourceAC 100V~240V ± 10%, 50Hz/60Hz; Consumption: 400VA
Dimensions & Weight380(W) x 148(H) x 454(D) mm; Approx. 15kg

AC Withstanding

Output-Voltage Range0.050kV~5.000kV
Output-Voltage Resolution1V
Output-Voltage Accuracy±(1% of setting + 5V) [no load]
Maximum Rated Load200 VA (5kV/40mA)
Maximum Rated Current40mA (0.5kV< V ≦5kV) 10mA (0.05kV≦ V ≦0.5kV)
Output-Voltage WaveformSine wave
Output-Voltage Frequency50 Hz / 60 Hz selectable
Voltage Regulation±(1% + 5V) [maximum rated load → no load]
Voltmeter Accuracy±(1% of reading + 5V)
Current Measurement Range1μA~40.00mA
Current Best Resolution1μA / 10μA
Current Measurement Accuracy±(1.5% of reading + 30μA)
Window Comparator MethodYes
ARC DetectYes
RAMP UP (Rise Time)0.1s~999.9s
RAMP DOWN (Fall Time)0.0s~999.9s
TIMER (Test Time)OFF, 0.3s~999.9s
WAIT TIME0.0s~999.9s
GNDON/OFF

DC Withstanding

Output-Voltage Range0.050kV~6.000kV
Output-Voltage Resolution1V
Output-Voltage Accuracy±(1% of setting + 5V) [no load]
Maximum Rated Load50W (5kV/10mA)
Maximum Rated Current10mA (0.5kV< V ≦6kV) 2mA (0.05kV≦ V ≦0.5kV)
Voltage Regulation±(1% + 5V) [maximum rated load → no load]
Voltmeter Accuracy±(1% of reading + 5V)
Current Measurement Range1μA~10.00mA
Current Best Resolution0.1μA /1μA /10μA
Current Measurement Accuracy±(1.5% of reading + 3μA) when I Reading < 1mA ±(1.5% of reading + 30μA) when I Reading ≧1mA
Window Comparator MethodYes
ARC DetectYes
RAMP UP (Rise Time)0.1s~999.9s
RAMP DOWN (Fall Time)0.0s~999.9s
TIMER (Test Time)OFF, 0.3s~999.9s
WAIT TIME0.0s~999.9s
GNDON/OFF

Insulation Resistance

Output Voltage50V~1200V dc
Output-Voltage Resolution50V
Output-Voltage Accuracy±(1% of setting + 5V) [no load]
Resistance Measurement
Test Voltage (50V≦V≦100V)
Display Range (0.1MΩ~ 10.00GΩ)
Measurement Range / Accuracy0.1MΩ~1MΩ:±(5% of reading + 3 count) 1 MΩ~50MΩ:±(5% of reading + 1 count) 51MΩ~2GΩ:±(10% of reading + 1 count)
Test Voltage (150V≦V≦450V)
Display Range (0.1MΩ~ 20.00GΩ)
Measurement Range / Accuracy0.1MΩ~1MΩ:±(5% of reading + 3 count) 1 MΩ~50MΩ:±(5% of reading + 1 count) 51MΩ~2GΩ:±(10% of reading + 1 count)
Test Voltage (500V≦V≦1200V)
Display Range (0.1MΩ~ 50.00GΩ )
Measurement Range / Accuracy0.1MΩ~1MΩ:±(5% of reading + 3 count) 1 MΩ~500MΩ:±(5% of reading + 1 count) 501MΩ~9.999GΩ:±(10% of reading + 1 count) 10.00GΩ~50.00GΩ:±(20% of reading + 1 count)*
Voltage Regulation±(1% + 5V) [maximum rated load → no load]
Voltmeter Accuracy±(1% of reading + 5V)
Short-Circuit Current10mA max.
Output Impedance2kΩ
Window Comparator MethodYes
RAMP UP (Rise Time)0.1s~999.9s
RAMP DOWN (Fall Time)0.0s~999.9s
TIMER (Test Time)OFF, 0.3s~999.9s
WAIT TIME0.0s~999.9s
GNDON/OFF

Ground Bond

Output-Current03.00A~32.00A ac
Output-Current Resolution0.01A
Output-Current Accuracy3A≦ I≦ 8A:±(1% of reading + 0.2A) 8A<I≦ 32A:±(1% of reading + 0.05A)
Test-Voltage8Vac max (open circuit)
Test-Voltage Frequency50Hz/60Hz selectable
Ohmmeter Measurement Range1mΩ~ 650mΩ
Ohmmeter Measurement Resolution0.1mΩ
Ohmmeter Measurement Accuracy±(1% of reading + 2 mΩ)
Window Comparator MethodYes
TIMER (Test Time)0.3s~999.9s
Test MethodFour Terminal
GNDON/OFF

Continuity Test

Output-Current100mA dc (fixed)
Ohmmeter Measurement Range0.10Ω~ 70.00Ω
Ohmmeter Measurement Resolution0.01Ω
Ohmmeter Measurement Accuracy±(10% of reading + 2Ω)
Window Comparator MethodYes
TIMER (Test Time)0.3s~999.9s

Memory

Single Step MemoryMANU:100 blocks
Automatic Testing MemoryAUTO:100 blocks, manu per auto:10

Interface

Front panelREMOTE terminal, USB host
Rear panelRear Output, RS-232C , USB device, Signal I/O, GPIB (Optional)

Do you have a AC 200VA AC/DC Withstanding Voltage Electrical Safety Analyzer that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your AC 200VA AC/DC Withstanding Voltage Electrical Safety Analyzer calibrated today! Click Here!