Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

Soken DAC-VTC-7 - Current Transformer Checker

Current Transformer Checker

Soken

Category : Instrument Transformer Testing Set

by quote only Add to Cart

Documents:
Brochure

Overview
Features
Specifications
Calibration

An instrument transformer that rated secondary current (voltage) is very low is usually composed of
electric devices like electronic power meters, watt-hour meters or transducers, so that the secondary
current (voltage) can directly be supplied to electronic circuits in the devices. DAC-CTC-7 for CT and
DAC-VTC-7 for VT are applicable to test such transformers and measures ratio errors and phase angles
precisely.

 

Specimen and application

Measuring ratio errors and phase angles of low current transformers (CT) or low voltage transformers (VT) in watt-hour meters, smart meters, digital current meters, and different transducers.

 

Two-Mode to measure

Two measuring modes are available. One of them is a comparison measuring mode which compares a reference CT (VT) and a CT (VT) under test. Another one is an absolute measuring mode which measures only a CT (VT) under test. Because a suitable CT (VT) sorted from mass productions in the absolute measuring mode can be used as a reference one in the comparison measuring mode, no need to prepare any reference CT (VT) especially.

Soken DAC-VTC-7 - Current Transformer Checker
  • The wide Phase angle of 0.0 to 2000 minutes.
  • Fast measurement.
  • Light in weight and compact in size.
  • Simple operation and clearness display.

 

Measuring Range

Rated Voltage
Absolution measuring mode
Secondary Voltage Range0.1V – 10V
Primary Voltage110V, 63.5V
Comparison measuring mode
Secondary Voltage Range of VT Under Test0.1V – 10V
Secondary Voltage Range of Reference VT0.1V – 10V
Ratio Error0.00% - +/-20.00%
Phase Angle0.0mim - +/-2000min
Test Current/ Test Voltage range2% - 120% of rated Current / Rated Voltage
Test Frequency50/60Hz
Measuring Accuracy
Ratio Error +/- (3%Rdg+3digits) (+/- (3%Rdg+5digits)at <=5% of rated current)
Phase Angle +/- (3%Rdg+3digits) (+/- (3%Rdg+5digits)at <=5% of rated current)
Input Burden Less than 1VA
AC InputAC100V- 240V +/-10% 50/60Hz
InterfaceUSB
Judgment FunctionOutput PASS/FAIL judgment (dry contact)
Size W430 x D380 x H150 mm
WeightApprox. 8kg

Do you have a Current Transformer Checker that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Current Transformer Checker calibrated today! Click Here!