GW Instek PEL-5005G-600-350 - High Power DC Electronic Load (600V, 350A, 5kW)
GW Instek PEL-5000G series single-channel electronic load provides 150V/ 600V/ 1200V models with a power range of 4kW~6kW. PEL-5000G has a total of 9 models featuring different combinations of power, voltage, and current. It can test and verify the specifications of batteries, electric vehicle chargers/charging stations and electric vehicle batteries. PEL-5000G supports parallel connection for same voltage specification and different power models. PEL-5000G can support up to 8 units connected in parallel to provide a maximum power of 48kW.
For the scenario of Battery Charger testing, PEL-5000G specifically provides four battery discharge modes, namely CV+Current Limit test mode, CV+Power Limit test mode, CC mode and CP mode. Users can choose a suitable test mode according to the test requirements.
For Battery Discharge Function, users can set the discharge cut-off voltage, discharge time, or discharge capacity (Ah) in CC or CP mode to meet the battery testing requirements.
In order to meet the verification requirements of different DUTs, PEL-5000G provides a variety of test functions, Surge current test mode, automated OCP, OPP test functions and 150 sets of parameter storage function. The 1200V model of PEL-5000G not only provides full power output at 1000V, but also provides 60% power output at 1200V output, which is higher than the 50% power output of other manufacturers of similar electronic loads.
High-voltage batteries or chargers directly connected to the electronic load may cause damage to the electronic load. PEL-5000G has a built-in slow starter, which not only protects the DC load, but also saves the user's installation cost and setting time for measurement on 600V/1200V models.
The communication interfaces supported by PEL-5000G include GPIB, RS232, USB, and LAN. The power, voltage and current of each model are shown in the following table:
Power / Voltage |
150V |
600V |
1200V |
|||
4kW |
PEL-5004G-150-400 |
(400A) |
PEL-5004G-600-280 |
(280A) |
PEL-5004G-1200-160 |
(160A) |
5kW |
PEL-5005G-150-500 |
(500A) |
PEL-5005G-600-350 |
(350A) |
PEL-5005G-1200-200 |
(200A) |
6kW |
PEL-5006G-150-600 |
(600A) |
PEL-5006G-600-420 |
(420A) |
PEL-5006G-1200-240 |
(240A) |
- 5 digital V / A / W Meter can be displayed on Large LCD display simultaneously
- Flexible CC, CR, CV, CP, CV + CL, CV + PL, Dynamic and short circuit operation modes
- Not only CC, CR, and CP mode have parallel operation functions, but CV mode also has parallel operation functions
- Surge Test mode for Capacitive load for current rising transient test
- Voltage meter display can be configured as polarity positive (“+”) or negative (“-”)
- Master-slave control is up to 1 Master and 7 Slaves
- Optional Interface: GPIB, RS232, USB, LAN
- SEQ Load Mode's programmable function allows for ultra-high-speed step changes from 0.02 to 999000 ms in CC or CP mode
- Provide battery BMS protection test function
- Optional 9923 load current waveform generator to provide the battery actual discharge current waveform simulation
- Built-in test modes include Battery Discharge, BMS, Short circuit, OCP, OPP test modes
- Turbo mode can withstand up to 1.5 times the current and power electronic load within 2 sec. period, most fit BMS, Short circuit, OCP, OPP test
- Protection against V, I, W, and ℃
Normal Mode
Specs |
| ||||||||||||||||||||||||||
Protections |
| ||||||||||||||||||||||||||
Constant Current Mode |
| ||||||||||||||||||||||||||
Constant Resistance Mode |
| ||||||||||||||||||||||||||
Constant Voltage Mode |
| ||||||||||||||||||||||||||
Constant Power Mode |
| ||||||||||||||||||||||||||
Constant Voltage Mode + Current Limit Mode |
| ||||||||||||||||||||||||||
Constant Voltage Mode + Power Limit Mode |
| ||||||||||||||||||||||||||
Short / OCP / OPP Test Function |
| ||||||||||||||||||||||||||
BMS Test Mode*7 |
| ||||||||||||||||||||||||||
Surge Test Mode |
| ||||||||||||||||||||||||||
Batt Test Mode |
| ||||||||||||||||||||||||||
SEQ Load Mode (remode only) |
| ||||||||||||||||||||||||||
Dynamic Mode |
| ||||||||||||||||||||||||||
Conf Key Parameter |
| ||||||||||||||||||||||||||
Measurement |
|
General
Typical Short Resistance | 28.584mΩ |
Maximum Short Current | 350A |
Load ON Voltage | 0.4 ~ 100V |
Load OFF Voltage | 0 ~ 99.6V |
Power Consumption | 550VA |
Dimension(H x W x D) | 177mm x 440mm x 745mm |
Weight | 29kg |
Temperature*8 | 0 ~ 40°C |
Safety & EMC | CE |
Note *1: The power rating specifications at ambient temperature -25°C
Note *2: The range is automatically or forcing to range II only in CC mode
Note *3: If the operating current is below range 0.1%, the accuracy specification is 0.1% F.S.
Note *4: Power range = Vrange x Irange
Note *5: Turbo mode for up to 1.5x Current rating & Power rating support Surge, Bms, Short / OCP / OPP test function
Note *6: The best accuracy of OCP / OPP test is Istep / Pstep = 1%FS
Note *7: BMS Test function for Battery Management System Board SHORT, OCCP and OCDP Test
Note *8: Operating temperature range is 0~40 °C, All specifications apply for 25 °C±5 °C, Except as noted
Do you have a High Power DC Electronic Load (600V, 350A, 5kW) that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your High Power DC Electronic Load (600V, 350A, 5kW) calibrated today! Click Here!
There are currently no reviews for this product.
Recommended Accessories for the High Power DC Electronic Load (600V, 350A, 5kW)
USB Cable, USB 2.0, A-B Type, 1200mm
LAN Card for PEL/AEL-5000C Series
GPIB Cable, Double Shielded, 600mm