GW Instek ASR-6600-18 - 18 kVA AC/DC Rack Type Power Source
The Inception of ASR-6000 High Performance AC/DC Power Source Development
From the very moment Alpha Go defeated the human chess champion with its ultra-high-speed computing capability, artificial intelligence technology (AI) has developed rapidly around the world. Today, servers with advanced AI functions process tremendous amounts of data under the high-speed computing architecture of 2 CPUs + 8 GPUs.
However, AI servers require a huge amount of power to maintain high-speed computing! In order to meet this demand, the power, density, and efficiency of server power supplies have been greatly improved. High-power server power modules require high-efficiency conversion and saving of power consumption. AC single-phase input, HVDC 400V input or increased DC voltage output designs can be utilized to achieve this purpose.
In order to ensure power stability when high-power servers are operating, power modules with hot-swappable redundant power supply specifications (such as CRPS) have been widely applied in server racks. Power modules with redundant functions require testing of multiple power modules at a time to ensure that all modules can maintain normal operation during high power output. Due to the rapid changes in the development of server power supplies, GW Instek developed the brand-new flagship model ASR-6000 series to meet customer needs.
The ASR-6000 series has two models — ASR-6450 AC / DC 4.5kVA and ASR-6600 AC / DC 6kVA
ASR-6000 is the first stand-alone unit from GW Instek that supports AC single/three-phase input and output, and has rated DC power output. The series employs third-generation semiconductor silicon carbide (SiC) technology to create a 4U 6kVA high power density and high-performance AC /DC power source.
ASR-6000 has the ability to emulate more diverse power environment changes, such as balanced and unbalanced three-phase, phase loss, and features multichannel output function can test up to three DUTs at the same time, programmable output impedance adjustment, and built-in over 40 types of arbitrary waveform outputs. The invincible launch of GW Instek flagship model ASR-6000 demonstrates that GW Instek can provide a complete test solution for high-power AC sources. ASR-6000 is the MVP of GW Instek power sources.
ASR-6000 main application
- Server/communication power supply manufacturer
- 6kVA On-board charger
- Uninterruptible power supply system (UPS)
- AC inverter
- AC three-phase motor control, and protection device
- Military industry, scientific research, education
- Adopts third-generation semiconductor silicon carbide (SiC) technology to create a 4U 6kVA high-performance AC/DC power source with high power density
- AC input supports single-phase and three-phase, phase voltage 200V to 240V±10% (Delta or Y connection)
- 10 output modes: including external input signal frequency and mains synchronization (SYNC), external voltage controlled internal amplifier output (VCA)
- Multi-channel output function
- Supports 1P2W, 1P3W, 3P4W output
- AC maximum output phase voltage: 350Vrms line voltage: 700Vrms
- AC balanced and unbalanced three-phase, phase loss output functions
- Programmable output impedance adjustment
- Dual-channel voltage/current output monitoring function
- Voltage output rise time can be adjusted in three ranges
- Supports sequence editing and emulation output mode
- Powerful arbitrary waveform editing and output function, capable of editing and outputting tens of thousands of waveforms
- Advanced web server control to support data acquisition function
- 100th order harmonic measurement function
- Supports external parallel connection to increase output power
- Standard interfaces: RS-232C, USB, LAN
- Optional interfaces: CAN Bus, DeviceNet, GPIB
Input Ratings
Power type | Three-phase Three-wire Delta connection Three-phase Four-wire Y connection |
Voltage range*1 | 200 Vac to 240 Vac (Phase Voltage) 380 Vac to 460 Vac (Line Voltage) |
Frequency range | 47 Hz to 63 Hz |
Power factor*2 | 0.95 or higher (typ.) |
Efficiency*2 | 80 % or higher |
Maximum power consumption | 24 kVA or lower |
AC Output
Multi-phase output : Single-phase output |
| ||||||||||||||||||||||||||||||||||||
Multi-phase output : Polyphase output |
|
DC Output (only single phase output)
Output capacity | 18 kW | ||||||||||
Mode | Floating output, the N terminal can be grounded | ||||||||||
Voltage : Setting Range | -250.0 V to +250.0 V / -500.0 V to +500.0 V, Setting Resolution: 0.01 V / 0.1 V | ||||||||||
Voltage : Accuracy*15 | ±(|0.3 % of set| + 0.3 V / 0.6 V) | ||||||||||
Maximum current*16 | 180 A / 90 A | ||||||||||
Maximum peak current*17 | Four times of the maximum current | ||||||||||
Output Stability, Total Harmonic Distortion, Output voltage rising time and Ripple noise |
|
*1 Y connection is three-phase, five-wire, Delta connection is three-phase, four-wire.
*2. In the case of AC-INT mode, the rate output voltage, resistance load at maximum output current, 45 Hz to 65 Hz and sine wave output only.
*3. Can be only set in polyphase mode.
*4. For phase voltage setting in polyphase output. In balance mode all phase are collectively set and in unbalance mode each phases are individually set.
*5. For an output voltage of 10 V to 175 V / 20 V to 350 V, sine wave, an output frequency of 45 Hz to 65 Hz, no load, DC voltage setting 0V (AC+DC mode) and 23°C ± 5°C. For phase voltage setting in the polyphase output.
*6. Line voltage only can be set in balance mode.
*7. If the output voltage is higher than rated value, this is limited to satisfy the power capacity. If there is the DC superimmposition, the active current of AC+DC satisfies the maximum current. In the case of 40 Hz or lower or 400 Hz or higher, and that the ambient temperature is 40 degree or higher, the maximum current may decrease.
*8. With respect to the capacitor-input rectifying load. Limited by the maximum current.
*9. External power injection or regeneration which is over short reverse power flow capacity is not available.
*10. For 45 Hz to 65 Hz, the rated output voltage, no load and the resistance load for the maximum current, and the operating temperature range.
*11. L1, L2 and L3 phase can be set independ at independ mode in the polyphase output.
*12. Can be set only with independ mode in polyphase output.
*13. For an output voltage of 50V or higher, sine wave, same load and voltage condition for all phase.
*14. In the case of the AC mode and output voltage setting to 0 V, 23°C ± 5°C
*15. For an output voltage of -250 V to -10 V, +10 V to +250 V / -500 V to -20 V, +20 V to +500 V, no load, AC voltage set to 0V (AC+DC mode) and 23°C ± 5°C
*16. If the output voltage is higher than rated value, this is limited to satisfy the power capacity. If there is the AC superimmposition, the active current of AC+DC satisfies the maximum current. And the ambient temperature is 40 degree or higher, the maximum current may decrease.
*17. Instantaneous eithin 3 ms, limited by the maximum current at rated output voltage.
*18. For an output voltage of 75 V to 175 V / 150 V to 350 V, a load power factor of 1, stepwise change from an output current of 0 A to maximum current (or its reverse), using the output terminal on the rear panel.
*19. 50 % or higher of the rated output voltage, the maximum current or lower, AC and AC+DC modes, THD+N. For the polyphase output, it is a specification for phase voltage setting.
*20. For an output voltage of 100 V / 200 V, a load power factor of 1, with respect to stepwise change from an output current of 0 A to the maximum current (or its reverse). 10% ~ 90% of output voltage.
*21. For 5 Hz to 1 MHz components in DC mode using the output terminal on the rear panel.
Measured Value Display (All accuracy of the measurement functions is indicated for 23˚C± 5˚C.)
Voltage*1*2 |
| ||||||||||||||||||
Current*4 |
| ||||||||||||||||||
Power*7*8 |
| ||||||||||||||||||
Power factor |
| ||||||||||||||||||
Harmonic voltage Effective value (rms) Percent (%) (AC-INT and 50/60 Hz only)*11 |
*1. In the polyphase output, the specification is for phase voltage, and the DC average value display cannot be selected. | ||||||||||||||||||
Harmonic current Effective value (rms) Percent (%) (AC-INT and 50/60 Hz only)*11 |
|
*1. In the polyphase output, the specification is for phase voltage, and the DC average value display cannot be selected.
*2. Accuracy values are in the case that the output voltage is within voltage setting range.
*3. The accuracy is for output waveform DC or sine wave only.
*4. Accuracy values are in the case that the output current is 5% to 100% of the maximum current.
*5. The accuracy is for output waveform DC or sine wave only.
*6. In the polyphase output, these are the specifications for each phase.
*7. For an output voltage of 50 V or greater, an output current in the range of 10 % to 100 % of the maximum current, DC or an output frequency of 45 Hz to 65 Hz.
*8. The apparent and reactive powers are not displayed in the DC mode.
*9. For the load with the power factor 0.5 or higher.
*10. For the load with the power factor 0.5 or lower.
*11. The measurement does not conform to the IEC or other standard. Phase Voltage and Phase Current.
*12. For an output voltage of 10 V to 175 V / 20 V to 350 V.
*13. An output current in the range of 5 % to 100 % of the maximum current.
Others
Protections | UVP, OVP, OCP, OTP, OPP, Fan Fail, Peak and RMS Current Limit | ||||||
Display | TFT-LCD, 7 inch | ||||||
Memory function | Store and recall settings, Basic settings: 10 | ||||||
Arbitrary Wave |
|
General Specifications
Interface |
| ||||||||||||||||
Insulation resistance |
| ||||||||||||||||
Withstand voltage |
| ||||||||||||||||
EMC | EN 61326-1 (Class A) EN 61326-2-1/-2-2 (Class A) EN 61000-3-2 (Class A, Group 1) EN 61000-3-3 (Class A, Group 1) EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-8/-4-11 (Class A, Group 1) EN 55011 (Class A, Group1) | ||||||||||||||||
Safety | EN 61010-1 | ||||||||||||||||
Environment |
| ||||||||||||||||
Dimensions (mm) | 598(W)×1116(H)×906(D) (not including protrusions) | ||||||||||||||||
Weight | Approx. 200 kg |
A value with the accuracy is the guaranteed value of the specification. However, an accuracy noted as reference value shows the supplemental data for reference when the product is used, and is not under the guarantee. A value without the accuracy is the nominal value or representative value (shown as typ.). Product specifications are subject to change without notice.
Do you have a 18 kVA AC/DC Rack Type Power Source that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your 18 kVA AC/DC Rack Type Power Source calibrated today! Click Here!
There are currently no reviews for this product.