Test Products International 9040 - Ultra
Overview
Features
Specifications
Calibration
C-Trend Software gives you greater ease of use and flexibility. Store, analyze and report on all your vibration, lube and process parameters (e.g. oil pressures, lube volume, temperature, run hours, etc.) in one place. All information is just a click away. Color coded alarms highlight problems. Trend lines show problems before they happen. Data can be accessed anywhere on any machine, with optional networking software. Plant history is everything and C-Trend turns it into useful information with the click of a mouse!
- Automatically detects out of balance, misalignment, looseness and bearing defects
- Predictive analysis capabilities that accurately calculate time frame to failure
- Condition based monitoring analyzes bearing wear and gear degradation
- Automatic RFID measurement point identification
- Saves and reads measurement values to/from RFID tags with Optional RFID
- User selectable defined envelope filters and demodulation functionality
- Built-in IEPE (constant current) accelerometer power supply
- High resolution (0.3Hz) frequency spectra from 0Hz to 15kHz
- Rugged fully waterproof construction meets IP67 and MIL-STD-810F requirements.
| Model 9040 Ultra Specifications | ||
|---|---|---|
| Size | 8.7” x 3.7” x 1.8” (220 mm x 95mm x 45mm) | |
| Weight | 1.1 lb (500g)(not including accelerometer) | |
| Environmental | Water: MIL-STD-810F, Method 512.4 IP67 sealed against accidental immersing (1m for 30 min) Drop: MIL-STD-810F, Method 516.5, Procedure IV 26 drops from 1.22 m 6 additional drops at -4°F (-20°C) 6 additional drops at 140°F (60°C) Operating: -22° to 149°F (-30° to 65°C) Storage: -40° to 158°F (-40° to 70°C) Humidity: MIL-STD-810F, Method 507.4 Sand and Dust: IP67, Mil-STD-810F, Method 510.4, Procedures I and II |
|
| Power supply | Rechargeable battery (charger included) | |
| Battery life | Typically 8-20 hours operating time depending on backlight usage. |
|
| Frequency ranges | 0 Hz to 1 kHz 0 Hz to 15 kHz |
|
| Frequency Resolution | Up to 0.3 Hz 400, 800, 1600, 3200, 6400,12800, 25,600 or 51,200 lines FFT |
|
| Displayed Amplitude Units | Acceleration in g Velocity in mm/s ( or inches/s) Bearing noise in BDU (bearing damage units) |
|
| Displayed Frequency Units | Hertz (Hz), RPM or CPM | |
| Input range | +/- 50g with standard 25mV/g TPI accelerometer | |
| Dynamic range | 120 dB +/- 50g to +/- 0.0004g with standard accelerometer |
|
| Auto set up of VA diagnostic bands (RPM = run speed) |
Instability 0Hz - 0.75 x RPM Unbalance 0.75 x RPM - 1.5 x RPM |
|
| Envelope demodulation filters | Fully user selectable high pass and low pass filter cut off frequencies |
|
| Accelerometer Connection | Standard 10 pin IP67 connected smart accelerometer w/built-in ID and sensitivity calibration (nominally 25mV/g) |
|
| IEPE accelerometer interface | Constant current accelerometer power supply (+20 volts @ 2mA) can be switched off for use w/ BNC output control panels Supplied with BNC connection lead |
|
| Numeric Keypad or Touch screen operation | Stylus free collection of vibration data using numeric key pad or by touching screen |
|
| Included accessories | • Carrying case with neck strap • Stylus lanyard • Docking station |
|
Do you have a Ultra that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Ultra calibrated today! Click Here!