Test Products International 9040 - Ultra

 Ultra

Test Products International

Rated 0 / 5 (0 reviews)

Category : Condition Based Monitoring

by quote only add to cart

Documents:
Datasheet

Overview
Features
Specifications
Calibration

C-Trend Software gives you greater ease of use and flexibility. Store, analyze and report on all your vibration, lube and process parameters (e.g. oil pressures, lube volume, temperature, run hours, etc.) in one place. All information is just a click away. Color coded alarms highlight problems. Trend lines show problems before they happen. Data can be accessed anywhere on any machine, with optional networking software. Plant history is everything and C-Trend turns it into useful information with the click of a mouse!

 

  • Automatically detects out of balance, misalignment, looseness and bearing defects
  • Predictive analysis capabilities that accurately calculate time frame to failure
  • Condition based monitoring analyzes bearing wear and gear degradation
  • Automatic RFID measurement point identification 
  • Saves and reads measurement values to/from RFID tags with Optional RFID
  • User selectable defined envelope filters and demodulation functionality
  • Built-in IEPE (constant current) accelerometer power supply
  • High resolution (0.3Hz) frequency spectra from 0Hz to 15kHz
  • Rugged fully waterproof construction meets IP67 and MIL-STD-810F requirements.

 

Model 9040 Ultra Specifications
 Size  8.7” x 3.7” x 1.8” (220 mm x 95mm x 45mm)
 Weight  1.1 lb (500g)(not including accelerometer)
 Environmental  Water: MIL-STD-810F, Method 512.4
 IP67 sealed against accidental immersing
 (1m for 30 min)

 Drop: MIL-STD-810F, Method 516.5, Procedure IV
 26 drops from 1.22 m
 6 additional drops at -4°F (-20°C)
 6 additional drops at 140°F (60°C)

 Operating: -22° to 149°F (-30° to 65°C)

 Storage: -40° to 158°F (-40° to 70°C)

 Humidity: MIL-STD-810F, Method 507.4

 Sand and Dust: IP67, Mil-STD-810F, Method 510.4,
 Procedures I and II
 Power supply  Rechargeable battery (charger included)
 Battery life  Typically 8-20 hours operating time
 depending on backlight usage.
 Frequency ranges  0 Hz to 1 kHz
 0 Hz to 15 kHz
 Frequency Resolution  Up to 0.3 Hz
 400, 800, 1600, 3200, 6400,12800, 25,600
 or 51,200 lines FFT
 Displayed Amplitude Units  Acceleration in g
 Velocity in mm/s ( or inches/s)
 Bearing noise in BDU (bearing
 damage units)
 Displayed Frequency Units  Hertz (Hz), RPM or CPM
 Input range  +/- 50g with standard 25mV/g TPI  accelerometer
 Dynamic range  120 dB +/- 50g to +/- 0.0004g with
 standard accelerometer
 Auto set up of VA diagnostic bands
 (RPM = run speed)
 Instability 0Hz - 0.75 x RPM
 Unbalance 0.75 x RPM - 1.5 x RPM
 Envelope demodulation filters  Fully user selectable high pass and low
 pass filter cut off frequencies
 Accelerometer Connection  Standard 10 pin IP67 connected smart accelerometer
 w/built-in ID and sensitivity calibration
 (nominally 25mV/g)
 IEPE accelerometer interface  Constant current accelerometer power
 supply (+20 volts @ 2mA) can be switched
 off for use w/ BNC output control panels
 Supplied with BNC connection lead
 Numeric Keypad or Touch screen operation  Stylus free collection of vibration data using
 numeric key pad or by touching screen
 Included accessories  • Carrying case with neck strap
 • Stylus lanyard
 • Docking station

Do you have a Ultra that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Ultra calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Test Products International 9040 - Ultra

 Ultra

Name :

Email :

Title :

Review: