Fluke I3000-FLEX-4PK - Flex AC Current Clamp, 4 Pack
Overview
Features
Specifications
Calibration
The i3000 Flex is an ac current clamp can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers.
- Three ranges
- 30 A
- 300 A
- 3000 A, 1, 10 or 100 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm (7 in.)
- CAT III 600V safety rating
| Electrical Specifications | |
| Current ranges | 30 A |
| 300 A | |
| 3000 A | |
| AC rms | |
| Output sensitivity (AC-coupled) | 100 mV |
| 10 m | |
| 1 mV per A | |
| Load impedance | 100 kΩ minimum |
| Accuracy | at +25 °C |
| ± 1 % of range (45 Hz to 65 Hz) | |
| Linearity | 10 % to 100 % of range |
| ± 0.2 % of reading | |
| Noise | 8 mV ac rms (30 A) |
| 2 mV ac rms (300 A, 3000 A) | |
| Frequency range | 10Hz to 50kHz (-3 dB) |
| Phase error | < ± 1 º (45 Hz to 65 Hz) |
| ± 10 º (at 20 kHz) | |
| Position sensitivity | with cable > 25 mm from the coupling |
| ± 2 % of range | |
| External field | with cable > 200 mm from the head |
| ± 1 % of range | |
| Power supply | 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator or dedicated external power supply |
| Temperature coefficient | ± 0.08% of reading per °C |
| Working voltage | see safety standards section |
| 600 V AC rms or DC | |
| General Specifications | |
| Head circumference | 610mm (24in) |
| Head cable diameter | 14.3mm (0.56in) |
| Head bend radius | 38.1mm (1.5in) |
| Cable length (head to electronics) | 2 m (6.56 ft) |
| Output connection | 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter |
| Operating temperature range | -20 °C to +90 °C (-4 °F to 190 °F) (head) |
| -20 °C to +85 °C (-4 °F to 185 °F) (electronics) | |
| Strong temperature range | -40 °C to +105 °C (-40 °F to 221 °F) (head) |
| -20 °C to +85 °C (-4 °F to 185 °F) (electronics) | |
| Operating humidity | 15 % to 85 % (non-condensing) |
| Weight | 180 g (0.396 lb) (head) |
| 190 g (0.419 lb) (electronics) | |
| Safety standards | BS EN 61010-1: 2001 |
| BS EN 61010-2-032: 2002 | |
| BS EN 61010-031: 2002 | |
| 600 Vrms, Category III, Pollution Degree 2 | |
| Use of the probe on uninsulated conductors is limited to 600 V AC rms or dc and frequencies below 1 kHz | |
| EMC standards | EN 61326: 1998 +A1, A2, and A3 |
| Maximum conductor size | 610 mm or 914 mm, depending on model |
Do you have a Flex AC Current Clamp, 4 Pack that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Flex AC Current Clamp, 4 Pack calibrated today! Click Here!
There are currently no reviews for this product.