Fluke TiX560-60HZ - Infrared Camera

Infrared Camera

Fluke

Rated 0 / 5 (0 reviews)

Category : Infrared Thermometers / Cameras

by quote only add to cart

Documents:
User's Manual Datasheet

Overview
Features
Specifications
Calibration

Your view of infrared technology is about to change 180°

  • Easily navigate over, under and around objects with the 180° articulating lens and see the image before you capture it
  • Premium in-field viewing experience with the only 5.7 inch responsive touchscreen LCD in its class1 - 150 % more viewing area3
  • Enhanced image quality and temperature measurement accuracy – turn your 320 x 240 images into 640 x 480 images, that’s 4x’s the resolution and pixels with SuperResolution
  • Get an in-focus image with the touch of a button. LaserSharp® Auto Focus, exclusive to Fluke, uses a built-in laser distance meter that calculates and displays the distance to your designated target with pinpoint accuracy2
  • See, save and share from the field and connect to the largest selection of wireless test and measurement tools with Fluke Connect™

1Compared to industrial handheld infrared cameras with 320x240 detector
resolution as of October 14, 2014.
2Up to 30 meters (100 feet).
3Compared to a 3.5 inch screen.

  • The largest 5.7 inch responsive LCD touchscreen for a 320x240 infrared camera
  • 180° articulating lens for those tough shots
  • Premium image quality with leading spatial resolution for a 320x240 infrared camera¹
  • Get up to 4 times the resolution and pixels than standard mode with SuperResolution (up to 307,200 pixels) post image capture in the camera
  • LaserSharp® Auto Focus - utilizing precision laser technology, focus on your target with pinpoint accuracy and get the correct image and temperature measurements you need
  • Built-in laser distance meter - calculates the distance to your designated target up to 100 feet (30 meters) and displays the distance on the image
  • Quick and easy in-field analysis with IR-Fusion® technology and advanced touchscreen functions:
    • Continuous auto blend - easy identification of location and problem with visible and IR image blending
    • Continuous level and span adjustment
    • Combine multiple frames of data into one premium image with Image Sharpening
    • Filter mode for improved thermal sensitivity
  • Post capture image editing includes:
    • Emissivity
    • Background temperature
    • Transmissivity
    • Palettes
    • Color alarms
    • IR-Fusion
    • Enable/disable markers
  • Connect to the largest network of wireless test and measurement tools with Fluke Connect™ (not available in all countries)
  • Remote viewing and control options
  • Temperature measurements up to 1200 °C
  • Light and ergonomic design with neck and hand strap for all day use
  • Optional field installable wide angle and telephoto lenses

¹Compared to industrial handheld infrared cameras with 320x240 detector resolution as of October 14, 2014. 

 

Key Features

IFOV with standard lens (spatial resolution) 1.31 mRad
Detector resolution 320 x 240 (76,800 pixels)
Field of view 24 °H x 17 °V
Minimum focus distance 15 cm (approx. 6 in)
IFOV with optional telephoto lens 0.65 mRad
Field of view  12 °H x 9 °V
Minimum focus distance 45 cm (approx. 18 in)
IFOV with optional wide-angle lens 2.62 mRad
Field of view 46 °H x 34 °V
Minimum focus distance 15 cm (approx. 6 in)
SuperResolution* On camera and in software
Image sharpening Yes
LaserSharp® Auto Focus Yes, for consistently in-focus images. Every. Single. Time.
Laser distance meter Yes, calculates distance to the target for precisely focused images and displays distance on screen
Advanced manual focus Yes
Streaming video (remote display) Via USB or WiFi
Touchscreen display (capacitive) 14.4 cm (5.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Wireless connectivity Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available)
Fluke Connect™ app compatible Yes (where available)
Fluke Connect™ tool compatible Yes (where available). Connects wireless to select Fluke Connect™ enabled tools. Five simultaneous connections supported.
IR-Fusion® technology Yes
AutoBlend™ mode Yes
Picture-In-Picture (PIP) Yes
Continuous AutoBlend™ Set AutoBlend™ level across continuum
Rugged, ergonomic design for one-handed use Rotatable (articulating lens) >180 degrees
Thermal sensitivity (NETD) ≤ 0.045 °C at 30 °C target temp (45 mK)
Filter mode (NETD improvement) ≤ 0.03 °C at 30 °C target temp (30 mK)
Level and span Smooth auto and manual scaling
Touchscreen adjustable level / span Yes. Span and level can be easy and quickly set by simply touching the screen.
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.0 °C (3.6 °F)
Minimum span (in auto mode) 3.0 °C (5.4 °F)
Built-in digital camera (visible light) 5 megapixel industrial performance 
Frame rate 60 Hz or 9 Hz versions
Laser pointer Yes
LED light (torch) Yes
Digital zoom 2x, 4x, 8x

Data Storage and Image Capture

Extensive memory options Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
Image capture, review, save mechanism One-handed image capture, review, and save capability
Post-capture image editing (on camera) Yes. Conduct on camera analysis for in-field results.
Advanced text annotation Yes. Including standard shortcuts as well as user programmable options.
File formats Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
Memory review Thumbnail view navigation and review selection
Software SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App - full analysis and reporting software
Export file formats with SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided
IR-PhotoNotes™ Yes
Text annotation Yes
Video recording Standard and radiometric
File formats video Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3)
Remote control and operation (for special and advanced applications) Yes
Auto capture (temperature and interval) Yes

Battery

Batteries (field-replaceable, rechargeable) Two lithium ion smart battery packs with five-segment LED display to show charge level
Battery life Three hours continuous use per battery pack 
Battery charge time 2.5 hours to full charge
Battery charging system Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
AC operation AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Power saving User selectable sleep and power off modes

Temperature Measurement

Temperature measurement range (not calibrated below -10 °C) -20 °C to +1200 °C (-4 °F to +2192 °F)
Accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (both value and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes

Color Palettes

Standard palettes 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ palettes 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra

General Specifications

Color alarms (temperature alarms) High-temperature and low-temperature
Infrared spectral band 7.5 μm to 14 μm (long wave)
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 95 % non-condensing
Center-point temperature measurement Yes
Spot temperature Hot and cold spot markers
User-definable spot markers 3 user-definable spot markers
Center box Expandable-contractible measurement box with MIN-MAX-AVG temp
Safety  IEC 61010-1: Overvoltage Category II, Pollution degree 2
Electromagnetic compatibility IEC 61326-1: Basic EM Environment
CISPR11, Group 1, Class A
Australian RCM IEC/61326-1
US FCC CFR 47, Part 15 Subpart B 
Vibration 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop Engineered to withstand 1 meter (3.4 feet) drop with standard lens
Size (H x W x L) 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in)
Weight (battery included) 1.5 kg (3.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

* Coming soon via firmware upgrade

Fluke Connect is not available in all countries.

©2015 Fluke Corporation. All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher; iPad (in an iPhone frame on iPad); Samsung Galaxy S4 running Android 4.3.x or higher and Samsung Galaxy S, Nexus 5, HTC One and One M8 running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc. 


Do you have a Infrared Camera that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Infrared Camera calibrated today! Click Here!

 

There are currently no reviews for this product.

 

Review the Fluke TiX560-60HZ - Infrared Camera

Infrared Camera

Name :

Email :

Title :

Review: