Soken DAC-HIT-3 - High Voltage Insulating Tester

High Voltage Insulating Tester

Soken

Category : Insulation Tester

by quote only Add to Cart

Documents:
Brochure

Overview
Features
Information
Calibration

DAC-HIT-3 is a tester that has been developed to make automatic measurements of direct current tests of appliances such as high voltage rotating machines and stator coils. The measurement voltage is output between DC 0-10kV, and after selecting polarization index (PI) mode or leakage index (LI) mode, measurement is conducted automatically for the designated duration at the configured voltage. In addition, using the memory function, data can be stored at each time, and data can be checked by using the MEM keys in front of the tester.

Furthermore, the GP-IB interface that allows easy integration of automatic test systems is equipped so it can be used in insulation diagnostic systems.

 

Application

Direct current tests of high voltage rotating machines and stator coils.

 

Front Panel

  1. Measurement time, Memory No.
  2. Current and Resistance
  3. Test voltage
  4. Current/Resistance switch key
  5. Test Voltage Applying Key
  6. DC Voltage Change Switch

 

PI (polarization index) test: Measurement for 10 minutes at the designated voltage.

  • Data memory points: 24 points
  • Memory data intervals: 10-second intervals from 10 seconds to 1 minute, 30-second intervals from 1
  • minute to 10 minutes
  • PI = value at 1 minute after applying voltage/value at 10 minutes after applying the voltage

 

LI (leakage index) test: After the PI test (10 minutes), the leakage current is measured for 10 minutes in
discharging condition.

  • Data memory points: 48 points (including 24 points in the PI test)
  • Memory data intervals: 10-second intervals from 10 seconds to 1 minute, 30-second intervals from 1 minute to 10 minutes, 10-second intervals from 10 minutes to 11 minutes, 30-second intervals from 11 minutes to 20 minutes
  • LI = value at 10 minutes after applying voltage/value at 10 minutes after starting discharge

 

Connection Diagram

 

Soken DAC-HIT-3 - High Voltage Insulating Tester
  • Maximum output voltage
  • Polarization index (PI) and leakage index (LI) are automatically measured
  • GB-IB included suitable for optimization

 

General

AccessoriesMeasuring Cable (5M) x 1, AC Power Code x 1, Grounding Cable (5M) x 1, Accessory Bag x 1
Weight12kg
SizeW430*H200*D380(mm)
AC InputAC90 - 250V 50/60Hz
Analog OutputRange F.S +10V
InterfaceGP-IB
Measuring Accuracy
Votlage±5%±1digit FS
Current
200µA - 2mA±5%±1digit FS
200nA - 20µA±10%±1digit FS
Resolution
Insulation Resistance0.1MΩ (2mA Range)
Absorption current0.1nA (200nA Range)
Measuring Range
Insulation Resistance
2mA Range0-2mA (Maximum 999.9M ohm)
200µA range0-200µA (Maximum 9999M ohm)
20µA Range0-20µA (Maximum 99.99 G ohms)
2µA Range0-2µA (Maximum 999.9G ohm)
200nA Range0-200nA (Maximum 9999 G ohms)
1Mohm-9999G ohm
Absorption Current1x10-10 - 1x10-3A
Output VoltageDC 0-10000V negative polarity