Your Cart
(empty)
0
Tradeport Electronics
measurement is our business
Cart : (empty)

GW Instek GPP-3610H - Single-Channel Programmable DC Power Supply

Single-Channel Programmable DC Power Supply

GW Instek

Rated 0 / 5 (0 reviews)

Category : DC Power Supplies

by quote only add to cart

Documents:
Datasheet

Overview
Features
Specifications
Calibration

GPP programmable DC power supply series incorporates two new 360W models, namely the 36V/10A GPP-3610H and the 72V/5A GPP-7250. GPP-3610H provides high programming resolution (1mV/0.2mA) and readback resolution (0.1mV/0.2mA); GPP-7250 provides high programming resolution (2mV/0.2mA) and readback resolution (0.1mV/0.1mA), and the best low ripple noise characteristics ≦1mVrms ( 5Hz~ 1MHz) / ≦2mArms and  output transient recovery capability≦100us.

GPP-3610H and GPP-7250 provide a variety of display modes, including channel setting values, measurement values, and waveform display. Using the output monitoring function of the GPP series, users can set monitoring conditions according to their needs, generate an alarm or stop output during the measurement process, stop the measurement and protect the customer's DUT. The GPP series provides an output recorder function, the voltage/current of the output process can be recorded in the internal memory, and the results can be saved as (*.REC) or (*.CSV) file and transferred to a USB. The saved *.CSV can be later exported into Excel for analysis.

 

GPP-3610H and GPP-7250 are designed with a load function of up to 100W. The GPP-3610H provides 36V/10A power output, and has built-in maximum 36.5V constant voltage load (CV), maximum 10.2A constant current load (CC) and maximum 1kΩ constant resistance load (CR) functions. GPP -7250  provides 72V/5A power output, and has built-in maximum 72.5V constant voltage load (CV), maximum 5.2A constant current load (CC) and maximum 1kΩ constant resistance load (CR) functions.

The output of GPP-3610H and GPP-7250 provides the sequence output function, which not only allows users to edit the power output waveform, but also allows users to set a sequence of constant voltage (CV) or constant current (CC) load waveform. For example, sequential power output or dynamic load simulation testing. In order to simplify the settings of waveform editing, the GPP series has 8 built-in waveforms in the templet waveform from the sequence output function, including Sine, Pulse, Ramp, Stair Up, Stair Dn, Stair UpDn, Exp Rise, Exp Fall waveforms, providing users to apply for output directly.

The complete protection functions comprise OVP, OCP, OPP, and OTP. The protection mechanism of OVP, OCP, and OTP is implemented by hardware circuits. Compared with competitors that use software to implement protection, it has the advantage of fast response time. The OVP and OCP functions allow users to set the protection action point based on the conditions of the DUT. OPP only protects the operation of the load function. The delay function can set the length of time during which the power output is on or off.

In addition, the Trigger In/Trigger Out function can synchronize external devices. The intelligent temperature-controlled fan can adjust the speed according to the temperature of the power transistor to reduce unnecessary noise. The output value setting and Sequence/Delay/Recorder functions respectively provide 10 sets of internal storage memory, and can be exported/stored using a USB. In addition to standard LAN, RS-232 and USB remote interfaces, GPP-3610H and GPP-7250 also have optional GPIB interface to meet different user needs.

  • 4.3” TFT LCD Display
  • Programming resolution: 1mV/ 0.2mA (GPP-3610H); 2mV/0.2mA (GPP-7250)
  • Readback resolution: 0.1mV/ 0.1mA
  • Low ripple noise: ≦ 1mVrms / ≦2mArms
  • Transient response time: ≦100us
  • Load function (CC, CV, CR mode)
  • Utilizes hardware to realize over voltage protection / over current protection / over temperature protection
  • Delay function/output monitoring function /output recorder function
  • Supports setting value, measurement value and output waveform display
  • Sequential output function and 8 built-in template waveforms
  • The output recorder function records the output voltage & current parameters with a minimum recording interval of 1 second
  • Sequence/delay/recorder/panel setting conditions respectively provide 10 sets of internal storage memory
  • Intelligent temperature-controlled fan effectively reduces noise
  • Standard interface: LAN, RS-232, USB, Ext I/O
  • Optional interface (manufacturer installed only): GPIB

 

Output Mode

Number of Channel CH1
Voltage0 ~ 36.000V
Current0 ~ 10.0000A

 

Constant Voltage Operation

Line Regulation≤ 0.01% + 3mV
Load Regulation≤ 0.01% + 5mV
Ripple & Noise (5Hz-1MHz)≤2mVrms
Transient Recovery Time≤100µs (50% load change,minimum load
Temperature Coefficient≤ 300ppm/°C

 

Constant Current Operation

Line Regulation ≤ 0.01% + 3mA
Load Regulation≤ 0.01% + 3mA
Ripple & Noise ≤ 2mArms

 

Resolution

Programming ( Voltage/Current )1mV / 0.2mA
Reedback ( Voltage/Current )0.1mV / 0.2mA

 

Meter

Full Scale ( Voltage/Current )36.5000V / 10.2000A
Programming Resolution ( Voltage/Current )5 digits / 6 digits
Reedback Resolution ( Voltage/Current ) 6 digits / 6 digits
Setting Accuracy
Voltage± (0.03% of reading + 10mV)
Current± (0.3% of reading + 10mA)
Readback Accuracy
Voltage± (0.03% of reading + 10mV)
Current± (0.3% of reading + 10mA)

 

DC Load Mode

Display
Voltage1 ~ 36.50V
Current0 ~ 10.200A
Power0 ~ 100.00W
CV Mode
CH11.500V ~ 36.50V
Setting/Reedback Accuracy ≤±(0.1% + 30mV)
Resoltion10mV
CC Mode
CH10 ~ 10.200A
Setting/Reedback Accuracy≤±(0.3% + 10mA)
Resoltion1mA
CR Mode
CH1 1Ω ~ 1kΩ
Setting/Reedback Accuracy≤±(3% + 1Ω)
(voltage≥0.1V, and current≥0.1A)
Resoltion

 

Protection

OVP
Power ModeOFF,ON(0.5V ~ 38.0V)
Load ModeOFF,ON(1.5V ~ 38.0V)
Setting Accuracy±100mV
Resolution100mV
OCP
Power ModeOFF,ON(0.05A ~ 10.5A)
Load ModeOFF,ON(0.05A ~ 10.5A)
Setting Accuracy±20mA
Resolution10mA

 

General

Operation EnvironmentIndoor use, Altitude: ≤ 2000m
Ambient temperature: 0 ~ 40°C / Relative humidity: ≤ 80%
Installation category: II / Pollution degree: 2
Storage EnvironmentTEMPERATURE: -10˚C ~ 70˚C / HUMIDITY: ≤70%
Power InputAC 100V/120V/220V/230V±10%, 50/60Hz
Power Consumption900VA, 680W
Dimensions & Weight213 (W) x 145 (H) x 362 (D) mm ; Approx. 10kg

Do you have a Single-Channel Programmable DC Power Supply that needs to be calibrated?

We offer standard traceable calibration and ISO 17025 accredited calibration services.

Get your Single-Channel Programmable DC Power Supply calibrated today! Click Here!

 

There are currently no reviews for this product.

 