GW Instek GDS-840S - Instek MHz, 2-channel, Mono LCD Display DSO
Overview
Features
Specifications
Calibration
- 250MHz Bandwidth with Monochrome (320*240) 5.7 LCD Display
- 125k Memory and 12 Division Horizontal Display
- 25GS/s Sampling Rate for Repetitive Waveforms
- 15 Auto Measurement Functions to get quick and accurate results
- Advanced Trigger : Pulse Width , TV Line, Event Delay and Time Delay
- GO-No Go, Learn Mode and Auto Setup Sequence
- FFT Function
- Standard Interface: USB, RS232, Printer Port, Option: GPIB Interface
- 250MHz Bandwidth with Monochrome (320*240) 5.7 LCD Display
- 125k Memory and 12 Division Horizontal Display
- 25GS/s Sampling Rate for Repetitive Waveforms
- 15 Auto Measurement Functions to get quick and accurate results
- Advanced Trigger : Pulse Width , TV Line, Event Delay and Time Delay
- GO-No Go, Learn Mode and Auto Setup Sequence
- FFT Function
- Standard Interface: USB, RS232, Printer Port, Option: GPIB Interface
SPECIFICATIONS | ||||||||||||
|
|
|||||||||||
Display Device |
|
|||||||||||
Display Contrast |
Adjustable
|
|||||||||||
Waveform Display Graticule |
8 x 10 divisions (8 x 12 div, when menu off)
|
|||||||||||
Display Mode |
Dot, Vector, Accumulate
|
|||||||||||
|
||||||||||||
Vertical System |
||||||||||||
Bandwidth (-3dB) |
|
|||||||||||
Channels |
2
|
|||||||||||
Resolution |
8 bit
|
|||||||||||
Sensitivity |
2mV / DIV ~ 5V / DIV
|
|||||||||||
Accuracy |
+3%
|
|||||||||||
Rise Time |
|
|||||||||||
Input Coupling |
AC, DC, GND
|
|||||||||||
Input Impedance |
1MΩ + 2%, ~ 22pF
|
|||||||||||
Polarity |
Positive& Negative
|
|||||||||||
Maximum Voltage Between Signal and Common at input BNC |
300V (DC + AC peak), CAT II
|
|||||||||||
Waveform Signal Process |
CH1-CH2, CH1+CH2, FFT
|
|||||||||||
Offset Range |
2mV/div ~ 50mV/div: ±0.5V ; 100mV/div ~ 500mV/div: ±5V ; 1V/div ~ 5V/div: ±50V
|
|||||||||||
Bandwidth Limit |
20MHz (-3dB)
|
|||||||||||
|
||||||||||||
Horizontal System |
||||||||||||
Range |
1nS/DIV ~10S / DIV ; Roll: 250mS/DIV ~ 10S/DIV (1-2-5 increments)
|
|||||||||||
Modes |
MAIN, WINDOW, WINDOW ZOOM, ROLL, X-Y
|
|||||||||||
Accuracy |
+0.01%
|
|||||||||||
Delay Range |
Pre-trigger : 20 DIV, Post-trigger : 1000 DIV
|
|||||||||||
|
||||||||||||
Signal Acquisition System |
||||||||||||
Real-time Sample Rate |
100MSa/s maximum on each channel
|
|||||||||||
Equivalent Sample Rate |
25GSa/s maximum on each channel
|
|||||||||||
Record Length |
125k / CH
|
|||||||||||
Peak Detection |
10nS (500nS/DIV ~ 10S/DIV)
|
|||||||||||
Acquisition Mode |
Sample, Peak Detect, Average
|
|||||||||||
Average |
2, 4, 8, 16, 32, 64, 128, 256
|
|||||||||||
|
||||||||||||
Trigger System |
||||||||||||
Source |
CH1, CH2, LINE, EXT
|
|||||||||||
Modes |
AUTO-LEVEL, AUTO, NORMAL, SINGLE, TV, TIME DELAY, /EVENT DELAY, EDGE, PULSE WIDTH
|
|||||||||||
Coupling |
AC, DC, LF rej, HF rej, Noise rej
|
|||||||||||
Sensitivity |
|
|||||||||||
|
||||||||||||
External Trigger |
||||||||||||
Range |
+15V
|
|||||||||||
Sensitivity |
|
|||||||||||
Input Impedance |
1MΩ + 2%, ~ 22pF |
|||||||||||
Maximum Input |
300V (DC + AC peak), CAT II |
|||||||||||
|
||||||||||||
X-Y Mode |
||||||||||||
X-Axis Input / Y-Axis Input |
Channel 1 (CH1) / Channel 2 (CH2) |
|||||||||||
Phase Shift |
+3° at 100kHz |
|||||||||||
|
||||||||||||
Cursor & Measurement |
||||||||||||
Automated Voltage Measurement |
Vhi, Vlo, Vmax, Vmin, Vpp, Vavg, Vrms, Vamp
|
|||||||||||
Automated Time Measurement |
Rise Time, Fall Time, Duty Cycle, Frequency, Period, Positive Width, Negative Width
|
|||||||||||
Cursor Measurement |
Voltage difference between cursors (ΔV)
time difference between cursors (ΔT) Frequency difference between cursors (1/ΔT) |
|||||||||||
|
||||||||||||
Frequency Counter |
||||||||||||
Readout Resolution |
6 digits
|
|||||||||||
Range |
AC Coupled, 10Hz minimum to rated bandwidth
|
|||||||||||
Signal Source |
All available trigger source except the Pulse Width & Video Trigger mode
|
|||||||||||
|
||||||||||||
Control Panel Functions | ||||||||||||
Autoset |
Autoset adjust vertical (volt/DIV), horizontal (sec/DIV), and trigger level automatically
|
|||||||||||
Save/Recall |
Up to 15 sets of measurement conditions can be saved and recalled
|
|||||||||||
Waveform Trace Save/Recall |
2 sets of waveform can be saved and recalled
|
|||||||||||
|
||||||||||||
Interface | ||||||||||||
USB Interface |
|
|||||||||||
RS-232 Interface |
|
|||||||||||
Printer port |
|
|||||||||||
Go-No Go Output |
|
|||||||||||
GPIB Interface |
|
|||||||||||
|
||||||||||||
Power Source | ||||||||||||
Line Voltage Range |
100V ~ 240V AC, automatic selection
|
|||||||||||
Line Frequency |
48Hz ~ 63Hz
|
|||||||||||
Power Consumption |
85Watts, 95VA maximum, with fan
|
|||||||||||
|
||||||||||||
Accessories |
Power cord x 1 ;
Instruction manual x 1 ; GDS-820 Series: GTP-150A Probes(10:1/1:1) x 2 GDS-840 Series: GTP-250A Probes(10:1/1:1) x 2 |
|||||||||||
|
||||||||||||
Dimensions & Weight |
254(W) x 142(H) x 310(D) mm, Approx. 4.1kg |
Do you have a Instek MHz, 2-channel, Mono LCD Display DSO that needs to be calibrated?
We offer standard traceable calibration and ISO 17025 accredited calibration services.
Get your Instek MHz, 2-channel, Mono LCD Display DSO calibrated today! Click Here!